Example Description Status Message
B01LAGCRATEA3
Set AGC ramp rate on input 
channel A to 3 dB/sec. 
B01LAGCRATEA3
B01LAGCRATEB?
Query the AGC ramp rate on 
input channel B. 
B01LAGCRATEBx , where x is a number between 1 
and 5, depending on the current setting of the AGC 
ramp rate on input channel B. 
B01LAGCRATE*5
Set AGC ramp rate on input 
channels A-D to 5 dB/sec. 
B01LAGCRATE*ëëëë
B01LAGCRATE*ààêê
Set AGC ramp rate on input 
channels A-B to 1 dB/sec and 
AGC ramp rate on input 
channels C-D to 4 dB/sec. 
B01LAGCRATE*ààêê
B01LAGCRATE*?
Query AGC ramp rate on input 
channels A-D. 
B01LAGCRATE*abcd , where a-d are each 
between à and ë, depending on the current setting 
of the AGC ramp rate for each of the line input 
channels. 
8.76. LEC -- Enable or Disable LEC
This command sets or queries the status of the line echo canceller (LEC). 
This command is a boolean command. See 
Section 6.1 for more information on this type of command. 
This command is saved to non-volatile memory only as part of a preset. The state of this command will be 
restored after power-up only if a preset is saved and that preset is set to be the power-on preset. 
Example Description Status Message
B01LEC1
Enable LEC.
B01LEC1
B01LEC0
Disable LEC.
B01LEC0
B01LEC2
Toggle LEC state.
B01LECx , where x is 0 or 1 depending on the current state of the LEC. 
B01LEC?
Query LEC state.
B01LECx , where x is 0 or 1 depending on the current state of the LEC. 
8.77. LECMODE -- Set Amount of Double Talk Suppression used 
in the LEC.
This command sets the amount of double talk suppression used in the LEC on the telephone input (T). The 
values correspond to the following settings. 
● 1 = No Suppression
● 2 = Light Suppression
● 3 = Heavy Suppression
● 4 = Half Duplex
This command is an integer command. See 
Section 6.2 for more information on this type of command. The