Set gate threshold for manual
gating threshold to 12 dB for
inputs 1-2 and 15 dB for inputs 3-
4.
B01AMGATET*ÉÉôô
B01AMGATET*<3
Decrease gate threshold for
manual gating threshold by 3 dB
for all input channels.
B01AMGATET*abcd , where a-d will each be
between ä and Φ depending on the setting of the
gate threshold for each input channel. If this
command is issued after the example above, the
status message will be B01AMGATET*ììÉÉ .
B01AMGATET*?
Query gate threshold for manual
gating threshold for all input
channels.
B01AMGATET*abcd , where a-d will each be
between ä and Φ depending on the setting of the
gate threshold for each input channel. If this
command is issued after the example above, the
status message will be B01AMGATET*ììÉÉ .
8.20. AMGNOM -- Set Global Maximum Number of Open Mics for
Bus Automixer
This command sets the global maximum number of open mics (NOM) allowed for the specified bus
automixer. The NOM limit is a global limit, meaning that this applies to all bus automixers with the same
AMBUSID. In contrast, the AMNOM command is a local limit that applies to the two local automixers in the
EF2241.
The first argument of this command specifies the automixer number (1-2) to adjust. The second argument
specifies the NOM limit (1-64). Even though this is a channel integer command, use of the wildcard for
specifying the automixer number is not supported.
This command is a channel integer command. See
Section 6.3 and Section 6.2 for more information on this
type of command. The minimum and maximum values for this command are 1 and 64, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
B01AMGNOM13
Set global NOM for automixer 1 to a
maximum of 3 mics.
B01AMGNOM13
B01AMGNOM2?
Query current global NOM limit for
automixer 2 .
B01AMGNOM2x , where x is between 1 and 64
depending on the current setting of the global
NOM limit for automixer 2 .
8.21. AMHOLD -- Set Automixer Hold Time
This command sets or queries the hold time (in milliseconds) for both automixers. Note that the hold time is
set globally for both automixers.
This command is an integer command. See
Section 6.2 for more information on this type of command. The
minimum and maximum values for this command are 0 and 5000, respectively.

Table of Contents

Other manuals for Polycom Vortex EF2241

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2241 and is the answer not in the manual?

Polycom Vortex EF2241 Specifications

General IconGeneral
BrandPolycom
ModelVortex EF2241
CategoryTelephone Accessories
LanguageEnglish

Related product manuals