EasyManua.ls Logo

PRÜFTECHNIK VIBXPERT II - Comparing the Current Measurement with Historical Data; Reference Data

PRÜFTECHNIK VIBXPERT II
176 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-30
VIBXPERT II 05.2012
Comparing the current measurement with historical data/ reference
data
The following requirements must be met to be able to use this feature:
- Historical data for the respective measurement task exist in the
OMNITREND database.
- A data set has been declared as a reference in the OMNITREND
database.
- The data sets were loaded in VIBXPERT with the route.
- The display mode for route results is set to ‘Standard’ (see also
Devicesetupforroute,p.2-15).
To compare the current measurement with the reference data, pro-
ceed as follows:
• Afterthemeasurementiscompleted*,presstheMENUkeyinthe
measurement screen.
• Select‘Reference’andclickon‘Comparewithreference’(seebe-
low).
Whenoverallvalues arebeingmeasured,avaluetableappears;
for signal measurements, the data are displayed in a waterfall dia-
gram.
InaTrendingSpectrum,thedisplaydependsonwhichpanelofthe
results screen is activated: the upper panel containing the spec-
trum (-> waterfall) or the lower panel containing the band alarm
overallvalues(->trend)(seep.4-10).
To compare the current measurement with the historical data, pro-
ceed as follows:
• Afterthemeasurementiscompleted*,presstheMENUkeyinthe
measurement screen.
• Select‘Reference’andclickon‘Showhistory’.
When overall values are measured, a trend appears; for signal
measurements, the data are displayed in a waterfall diagram.
Left:
Calling up reference data
Right:
Compare current data with
reference & historical data
(characteristic values)
R: Reference data exist
* If the measurement is stored automat-
ically, the program subsequently jumps
to the measurement task screen.
Open the current measurement result as
follows:
- Highlight the measurement task icon.
- Press the MENU key, and click on ‘Dis-
play Result’ (see previous page).
Trend