3-37
VIBXPERT II 05.2012
Recording
Recording configuration
The number of results depends on the
available memory space
The configuration screen appears (see below).
Start conditions
immediately:Therecordingstartsimmediately(MENU->Start).
start in: The measurement recording begins after a set period (0 s ...
23:59:59h).
start at: The measurement recording begins at the set time (time,
date)orwhenthesetrpmisreached(0...1000Hz);risingorfall-
ing edge can be selected. For an rpm-controlled measurement, the
task must contain an rpm measurement.
delay:Speciesthetime/rpmchangebetweentwomeasurements.
Stop conditions
counter: The measurement is ended when the entered number of re-
sults has been measured (1 ... 10000).
run for: The measurement recording runs for the specified time (0 s
...23:59:59h).
stop at: The measurement stops at the specified time or when the set
rpmisreached(0...1000Hz);therisingorfallingedgecanbe
selected.
manual: The measurement stops when the memory card is full or
whentheESCkeyispressed.
Further settings
switch off Backlight: To save power when operating the device during
recording, the display illumination can be switched off permanent-
ly. This option is independent of the settings in the device setup (P.
2-13).
trigger: This option is only available if the measurement is triggered
viathesignallevel(see‘Trigger’,p.3-22).
‘Single’:The triggerconditionisonlyconsideredbeforethe rst
measurement.
‘Multi’: Only start each measurement when the trigger condition
has been met.
target file: The results and the configuration settings are saved in a
file. It is not possible to add multiple recording files.
The start, stop and delay conditions
can be independently controlled
according to time or rpm. For ex-
ample, recording can be set to start
at a certain time, but the next mea-
surements only take place after a
certain change in the rpm.