Chapter 7: Encryption Key Management
Scalar Key Manager Functions Available on the Library
Quantum Scalar i40 and Scalar i80 User’s Guide 193
Note: The key generation process takes 15 minutes to an hour,
depending on network performance and quantity of keys
already used. The library notifies you when the process
completes. During key generation and backup, the SKM server
will not be able to process any library requests for data
encryption keys. You should not run any library or host-initiated
operations on SKM partitions during key generation and
backup.
Caution: Avoid manually generating keys on more than five libraries
simultaneously as the key generation process is resource-
intensive on the server. Generating keys manually on more
than five libraries at once could result in a failure to
complete the key generation operation, or interfere with
key retrieval operations.
If a failure does occur during key generation, wait 10
minutes, then t
ry to start it again. The key generation
process will resume from where the error was encountered.
To manually generate data encryption keys:
1 Make
sure that both SKM servers are running and operational.
2 F
rom the library’s Web client, access the encryption partition
configuration screen (Setup > Encryption > Partition
Configuration)
. See Figure 35 on page 193.
Figure 35 Accessing the
Encryption Partition
Configuration Screen

Table of Contents

Other manuals for Quantum Scalar i40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i40 and is the answer not in the manual?

Quantum Scalar i40 Specifications

General IconGeneral
Power requirements100 - 240 V AC, 50 - 60 Hz, 2.8/1.4 Amps
Power consumption (typical)100 W
Expansion slots25
Dimensions (WxDxH)455 x 793 x 132 mm
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Product typeStorage auto loader & library
Product colorBlack
Weight and Dimensions IconWeight and Dimensions
Weight15800 g