Chapter 8
190 OmniSeed™ Viper Pro™ Installation & Operation Manual
Enabling Section Control Override
1. While in a job, touch the Section Status area on the main screen. The Section Control Setup screen
displays.
2. Using the on-screen keypad, enter a value, in seconds, in the Section Control Override Sec field.
3. During application, toggle the master switch on the Raven CAN switch box to the ‘OVERRIDE’ position.
Note: The override feature affects all enabled products. The time set as the override seconds does not
start until the master switch returns to the on position. Hold the master switch in the override
position to sustain the override countdown if desired.
4. Each product enabled will resume application at the target rate for the programmed override countdown
before the system will resume normal application control.