Remote Calibration Console
Remote Tank Console Operation
The remote tank console allows the operator to prime metering rollers, adjust valve response, perform a catch
test and enter the cal weight all while observing operation of the air cart to ensure proper operation of the
OmniSeed system.
Priming
To accurately calibrate the OmniSeed system for operation, the metering rollers must be primed and the meter
RPM set prior to performing a catch test. The operator may prime the metering rollers using the remote tank
console. To prime the metering rollers:
Note: Place the weight box below the appropriate bin to avoid dumping product on the ground. The
metering rollers will not stop automatically. Do not leave the remote tank console until the process
is complete and the metering rollers have stopped rotating.
1. With the remote tank console powered up, use the Next and Prev keys to select the desired bin and press
the Enter key.
2. Press the Begin key to start the bin calibration.
3. Press the Enter key again to select the ‘Prime Meter Roller’ option and press the Start key.
4. Allow the metering roller to rotate until a consistent amount of product is dispensed and then press the Stop
key.
If necessary, use the INC or DEC keys to increase or decrease the PWM Output, or speed, of the metering
roller during the priming process.
WARNING
The metering rollers will begin turning during
the priming procedure. Keep away from moving
components and alert anyone around the air
cart when performing the priming process.