To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
Manual No. 016-3001-015 Rev. C 193
OmniSeed Section Control
Create Section Control No-Apply Map Method
This method allows the operator to define apply and no-apply zones during the job. The apply/no-apply zones
may be created using the scouting features of the Viper Pro field computer. If this method is selected, the Viper
Pro prompts the operator to name the zone map that will be created.
Select the Create No-Apply Boundary option to create a no-apply area of three implement widths around the
completed field boundary. The automatic section control feature will function the same as in standard mode
until all apply/no-apply areas have been defined and the section control map is created. Refer to the How to
Create a Zone Map section on page 195 for details on creating a zone map on the field computer.
Load Section Control No-Apply Map Method
Select this method to load a map previously created and saved on the Viper Pro. Touch the Next button to view
a list of maps available in the Viper Pro memory. To proceed, select the desired section control map and touch
the Next button.