8
Manual No. 016-3001-015 Rev. C 195
OmniSeed Section Control
Section Control Apply/No-Apply Maps
A section control apply/no-apply map may be created on the Viper Pro before an actual job or product
application using the scouting function or the map may be created during the application. The first step in
creating a section control apply/no-apply map is to define the apply and no-apply zones within a field. These
zones are created in the same method as boundary fields.
Note: The apply and no-apply selections will only be available while creating a map.
How to Create a Zone Map
1. Start a new job.
2. Touch the Scout tab.
3. Select Record, then Zone. The Record Field Feature screen displays.
4. Select Apply or No-Apply.
Note: Only one zone type can be created at a time.
5. Select an offset shift for the boundary that is in relationship to one-half the implement width.
6. Touch OK. Viper draws the boundary line on the Scout map as the machine drive travels along the zone
boundary.
7. To close the boundary, touch Finish.
Note: Apply/no-apply zones do not have the auto close feature. Touch the Finish button and select the
Zone to finish at the end of the boundary.
8. To define additional apply/no-apply zones, repeat step 3 through 7 for each apply or no-apply boundary to
define.