9
Manual No. 016-3001-015 Rev. C 201
Remote Calibration Console
Cal Weight
The Metered Weight Page will display automatically at the end of the catch test procedure. This screen
displays the number of metering roller revolutions detected during the catch test and allows the operator to
enter the weight of product dispensed to calibrate the OmniSeed system. To enter the cal weight value:
1. Use the Left and Right keys to move the cursor below the bin cal weight value to the first digit of the
measured cal weight and press the Enter key.
2. Press the INC or DEC keys to set the appropriate value for the selected digit and press the Enter key to set
the value.
3. Repeat the above procedure to set the remaining cal weight digits up to two decimal places.
4. To program the cal weight value, press the Right key to move the cursor past the last decimal place in the
cal weight value and press the Send key.
The remote tank console will send the entered cal weight value to the appropriate control node and will
return to the bin calibration screen.
5. Press the Exit key to return to the bin selection screen.
Product or Cal