Manual No. 016-3001-015 Rev. C 247
9. Drive the test distance.
10. At the end of the measured test distance, touch the End Cal Run button. The new speed cal value will be
calculated automatically.
11. Touch Yes and the new speed cal will be applied.
Note: Touch No to discard the calculated speed cal and continue using the existing value.
Verification of the Speed Cal Value
The following procedure may be used to verify the speed cal currently entered on the field computer.
1. Make sure any section switches are turned OFF before powering the field computer ON.
2. Touch the Product Control area at the bottom of the main screen to display the CAN Controller Status
screen.
3. Touch the Tally Registers button at the bottom of the screen.