Appendix B
264 OmniSeed™ Viper Pro™ Installation & Operation Manual
Verifying Flow Rate Limits
The target rate for an application must be within the range of that specified for the Raven flow meter installed.
Pressure Transducer
Calibrating the Pressure Transducer
1. Read the pressure on an analog gauge connected in line with the pressure transducer.
Note: If no pressure gauge is installed in line with the pressure transducer, bleed or relieve any pressure
applied to the transducer and enter a value of ‘0’ for the pressure value in the procedure below.
2. Touch the Pressure area on the CAN Controller Status screen.
Note: Each product node or control channel has two pressure settings. Use the Next or Prev buttons to
display the correct pressure transducer to calibrate before proceeding.
3. Touch the Pressure value and use the on-screen keyboard to enter the pressure gauge reading
4. Touch Set to calibrate the pressure transducer.
5. Touch OK to return to the CAN Controller Status screen.
Flow Meter Model Flow Range
Average Meter
Cal Value
RFM 5 0.05 - 5 GPM [0.2 - 18.9 lit/min] 5500
RFM 15 0.3 - 15 GPM [1.1 - 56.8 lit/min] 1750
RFM 60P 1 - 60 GPM [3.8 - 210 lit/min] 720
RFM 100 3 - 100 GPM [11.4 -380 lit/min] 700
RFM 200/ 200 Poly 15 - 200 GPM [56.8 - 760 lit/min] 164
RFM 400 25 - 400 GPM [94.6 - 1515 lit/min] 80