12. Timer (Three-phase Motor Control Timer Function)
puorG92/C61M
page 133
854fo7002,03.raM21.1.veR
2110-1010B90JER
Figure 12.32 TA1MR, TA2MR, TA4MR, and TB2MR Registers
Bit Name
Timer Ai Mode Register
Symbol Address After Reset
TA1MR 0397
16
00
16
TA2MR 0398
16
00
16
TA4MR 039A
16
00
16
Function
Bit Symbol
b7 b6 b5 b4 b3 b2 b1 b0
Operation mode
select bit
Set to 10
2
(one-shot timer mode) for the
three-phase motor control timer function
TMOD1
TMOD0
MR0
Pulse output function
select bit
Set to 0 for the three-phase motor control
timer function
MR2
MR1
MR3
Set to 0 for the three-phase motor control timer function
0 0 : f
1
or f
2
0 1 : f
8
1 0 : f
32
1 1 : f
C32
b7 b6
TCK1
TCK0
Count source select bit
100
Set to 1 (selected by event/trigger select
register) for the three-phase motor control
timer function
Trigger select bit
External trigger select bit
RW
Timer B2 Mode Register
Symbol Address After Reset
TB2MR 039D
16
00XX0000
2
Bit Name Function
Bit Symbol RW
b7 b6 b5 b4 b3 b2 b1 b0
Operation mode select bit
Set to 00
2
(timer mode) for the three-
phase motor control timer function
TMOD1
TMOD0
MR0
MR2
MR1
MR3
TCK1
TCK0
Count source select bit
0
0
1
0
No effect for the three-phase motor control
timer function
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RO
No effect for the three-phase motor control timer function.
If necessary, set to 0. When read, the contents are undefined
Set to 0 for the three-phase motor control timer function
0
RW
When write in three-phase motor control timer function, write 0.
When read, the content is undefined
b7 b6
0 0: f
1
or f
2
0 1: f
8
1 0: f
32
1 1: f
C32