Transport Belt Charge Adjustments 
SM 4-39 J007/J010/J011 
J007/010/ 
J011 
SP 
No. 
Menu Title  Meaning  SP No. 
1218 CHG:PITCH:C3 Charge ID Table: 25% to 35% Humidity (Mj3)  1218 
1219 CHG:PITCH:C4 Charge ID Table: 35% to 45% Humidity (Mj3)  1219 
1220 CHG:PITCH:C5 Charge ID Table: 45% to 55% Humidity (Mj3)  1220 
1221 CHG:PITCH:C6 Charge ID Table: 55% to 65% Humidity (Mj3)  1221 
1222 CHG:PITCH:C7 Charge ID Table: 65% to 75% Humidity (Mj3)  1222 
1223 CHG:PITCH:C8 Charge ID Table: More than 75% Humidity (M3)  1223 
1224  CHG:PITCH:D1  Charge ID Table: Less than 10% Humidity (Mj4)  1224 
1225 CHG:PITCH:D2 Charge ID Table: 10% to 25% Humidity (Mj4)  1225 
1226 CHG:PITCH:D3 Charge ID Table: 25% to 35% Humidity (Mj4)  1226 
1227 CHG:PITCH:D4 Charge ID Table: 35% to 45% Humidity (Mj4)  1227 
1228 CHG:PITCH:D5 Charge ID Table: 45% to 55% Humidity (Mj4)  1228 
1229 CHG:PITCH:D6 Charge ID Table: 55% to 65% Humidity (Mj4)  1229 
1230 CHG:PITCH:D7 Charge ID Table: 65% to 75% Humidity (Mj4)  1230 
1231 CHG:PITCH:D8 Charge ID Table: More than 75% Humidity (Mj4)  1231 
Changing one humidity setting for one item of a row in a service table sets the 
temperature settings for the entire row. (See the "SP No." columns of Tables 3-1 to 3-8.) 
Note that the same Charge ID appears many times in the rows of the 
Temperature/Humidity Tables.  
The table below shows how the system reads and records the number of times Charge 
ID1, Charge ID2, and Charge ID3 is repeated in each row of the Temperature/Humidity 
Table. These readings are used to the determine the final settings.  
 
Fig. 3-1 How Settings of the Charge ID Table Are Determined *
*T920