SP Tables
SM 5-17 J007/J010/J011
J007/J010
J011
Set Charge for Target Market
1238 CHG:REGION Set Charge for Geographic Region
Use the SP to set the charge for the areas listed below.
0: Enable geographical area setting
1: Japan
2: NA (North America)
3: Europe
4: China (Mainland)
5: China (Taiwan) "5" and "4" refer to same pitch table.
6: Asia. "4" "5" "6" refer to same charge pitch table
If any item other than "0" is selected that item and its setting is enabled and
takes priority.
[0 to 6/0/1/---]
Print Head Temperature Thresholds
1300 HTEMP:H:STOP Trigger Shutdown: Standby, Printing
1301 HTEMP:H:JUDG Trigger Shutdown: Power On
1302 HTEMP:H:RCVR Recovery After High Temp Shutdown
1303 HTEMP:L:RCVR Recovery After Low Temp Shutdown
1304 HTEMP:L:JUDG Trigger Shutdown: Power On
1305 HTEMP:L:STOP Trigger Shutdown: Standby, Printing
Use this SP to set the threshold for the operating temperature range of the print
head.
[0 to 1000/0/1/0.1
o
C
Ambient Temperature Thresholds
1306 ETEMP:H:STOP High Temperature to Trigger Shutdown: Standby, Printing
1307 ETEMP:H:JUDG High Temperature to Trigger Shutdown: Power On
1308 ETEMP:H:RCVR Recovery After High Temp Shutdown
1309 ETEMP:L:RCVR Recovery After Low Temp Shutdown
1310 ETEMP:L:JUDG Low Temperature to Trigger Shutdown: Power On
1311 ETEMP:L:STOP Low Temperature to Trigger Shutdown: Standby, Printing
Use this SP to set the threshold for the operating humidity range of the print
head.
[0 to 1000/0/1/0.1
o
C