J007/J010/J011 34 Repair Center Manual
Temperature
Room temperature too high
Description: Ambient temperature is above 43
o
C.
Probable Cause: Signal of the print head temperature sensor did not change, or signal of
the PFU relay sensor did not change.
Location: Temperature/humidity sensor, print head temperature sensor, control board
Service Center Procedure:
1. Determine if ambient temperature is out of range (10
o
C to 32
o
C (50
o
F to 89.6
o
F).
2. Try again once the temperature is within range.
Replacement Procedure:
1. Replace control board.
Room temperature too low
Description: Ambient temperature is below 0
o
C.
Probable Cause: Signal of the print head temperature sensor did not change, or signal of
the PFU relay sensor did not change.
Location: Temperature/humidity sensor, print head temperature sensor, control board
Service Center Procedure:
1. Determine if ambient temperature is out of range (10
o
C to 32
o
C (50
o
F to 89.6
o
F).
2. Try again once the temperature is within range.
Replacement Procedure:
1. Replace control board.
Tray
Tray selection error
Description: The tray selection is incorrect.
Probable Cause: The tray selection is incorrect.
Location: None
Service Center Procedure:
1. Check printer driver settings to determine if selected paper tray is the same as
the tray selected in printer operation panel.
2. Select the appropriate setting.
3. Check printer driver settings.
Replacement Procedure:
None