SP Tables
SM Appendix 3-25 M047
Appendix: SP
Mode Tables
003
Cancellation On/Off
[0 to 1 / 0 / 1]
0: OFF (Lockout is not cancelled.)
1: ON (Lockout is cancelled if a user ID and
password are correctly entered after the lockout
function has been executed and a specific time has
passed.)
Turns on or off the cancellation function of the account lockout.
004
Cancellation Time
[1 to 9999 / 60 / 1 min]
Sets the interval of the retry for accessing the local address book account
after the lockout function has been executed.
This setting is enabled only if SP5413-3 is set to "1" (ON).
5414
Access Mitigation
001
Mitigation On/Off
Permits or does not permit consecutive access to the machine with the
same ID and password.
[0 to 1 / 0 / 1]
0: Off (Permitted)
1: On (Not permitted)
002
Mitigation Time
Sets the prohibiting time for consecutive access to the machine with the
same ID and password.
[0 to 60 / 15 / 1 min]