SP Tables
M047 3-44 SM Appendix
5816 201
Instl: Condition
Displays a number that indicates the status of the @Remote service device.
0: Neither the registered device by the embedded RCG nor embedded RCG
device is set.
1: The embedded RCG device is being set. Only Box registration is
completed. In this status the external RCG unit cannot answer a polling
request.
2: The embedded RCG device is set. In this status the external RCG unit
cannot answer a polling request.
3: The registered device by the embedded RCG is being set. In this status
the embedded RCG device cannot be set.
4: The registered module by the embedded RCG has not started.
5816 202 Instl: ID #
Allows entry of the number of the request needed
for the embedded RCG device.
5816 203 Instl: Reference
Executes the inquiry request to the @Remote
GateWay URL.
5816 204
Instl Ref Result
Displays a number that indicates the result of the inquiry executed with
SP5816 203.
0: Succeeded
1: Inquiry number error
2: Registration in progress
3: Proxy error (proxy enabled)
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or password)
6: Communication error
7: Certification update error
8: Other error
9: Inquiry executing