191
The output would not be high until all the pre-defined short messages were successfully sent out.
Connection
Description
Input Trg
Start sending short message out (Trigger)
Input R
Only reset the output signal to 0.
Output Q
Q is switched on after all the short message sent out
successfully.
General description of parameter dialog box:
1.Message Format TEXT or PDU (UCS2).
TEXT is supposed to support ASCⅡ.
PDU is supposed to support multi languages.
2. Short message content edit area: Up to 100 characters are available under TEXT mode and up to 70
characters under PDU (UCS2) This area is only for the “Text Message”
3. With confirmation function activated:
If the x-Messenger does not receive an acknowledgement SMS within a certain preset time from the receiver,
the event message will be sent to the next receiver. This means that the device runs through the 5 allocated
receiver numbers and restarts afterwards with the first number again (The number of running loops can be
pre-defined). As soon as the device receives a confirmation from the receivers the process is stopped. If this
is not the case, the message will be sent to the next receiver (after expiry of the preset time).
If the confirmation is inactive, all receivers who are allocated to that event will receive a message without

Table of Contents