2. LAN Address Disposal
User shall assign x-Messenger CPU’s communication port for GPRS to IP address of server PC. e.g. “5002” is
just x-Messenger CPU’s communication port for GPRS, and “5001” had been assigned to computer 1 as well,
further let’s suppose 192.168.0.119 is just IP address for server PCcomputer1, in above sketch map, then
Port “5002” shall be assigned to 192.168.0.119 in Router’s configuration. In addition, the said
communication port refers to the one to be configured via eSmsConfig, furthermore, such configuration
would be downloaded to x-Messenger CPU.
Click the menu “SMS->Set GPRS params to set the server port number.
Please note that PORTs assigning method is subject to various routers, hence, user shall consult your local
router suppliers for specific assigning method.
For instance, if the static IP address user had applied is 221.226.189.74, then such IP address shall be
treated as server address to be connected by all x-Messenger CPUs(EXM) involved in the network. Please