RTC=89-01-09,01:32:09,0;
This is used to change the Real time clock of x-Messenger, Year-month-day,hour:minute:second,week;
0: Sunday
1: Monday…..
Note: The parameters can include one or more items as above shows, for example, you want to modify
the phone number, you only need to edit message as follows:
##**
Msg,I01,1,I01,2,I01,3,I01,4,I01,5,I02,1,I02,5,I03,2,I03,4,I03,5:10987654321;
(Note: This command is only for 2G version unit, it is unavailable for 4G version unit)
This function also can be used between two individual x-Messengers CPU.
For example:
GMS
Locally Remote
The Analog input1 & Analog input2 of remote station can be sent to the local one by means of SMS.
The SMS message can be configured like this:
This parameter can be configured in the sms message output block.