SDT Require
BAT Presence:
If enabled an alarm will be generated if BAT is not present in the stream.
Default: Disabled
EIT:
Enable or disable alarming of Event Information Table errors. Only
relevant when DVB mode is selected.
EIT Maximum
interval Actual (ms):
The maximum allowed section repetition interval for the EIT Actual table.
Default: 2 000 ms
EIT Minimum
gap interval (ms):
The minimum allowed section gap interval for the EIT tables. Default:
25 ms
EIT Required
Table IDs:
If one or more table IDs are specified an alarm will be generated if
these table IDs are not present in the stream on the EIT PID. Entries
should be separated by commas, or a range may be specified. Example:
‘78,79,80-85’ Default: Disabled
EIT Verify that
present event is
transmitted
If enabled, an alarm will be raised if one or more services don’t have a
present event transmitted in the EIT (i.e. no EPG for the current program)
EIT Check valid
time for present event
If enabled, an alarm will be raised if time signaled for the present event
(the current program) is not correct. The maximum offset from the
current time can be configured.
EIT Maximum timing
error for present event(s)
The maximum timing error to allow for the present event. If the current
time is not inside the program start/stop times by this margin then an
alarm will be raised.
EIT Verify that
following event is
transmitted
If enabled, an alarm will be raised if one or more services don’t have a
following event transmitted in the EIT (i.e. no EPG for the next program)
RST:
Enable or disable alarming of Running Status Table errors. Only relevant
when DVB mode is selected.
RST Maximum
interval (ms):
The maximum allowed section repetition interval for the RST table. De-
fault: 20 s
TDT:
Enable or disable alarming of Time Date Table errors. Only relevant
when DVB mode is selected.
TDT Maximum
interval (ms):
The maximum allowed section repetition interval for the TDT and TOT
tables. Default: 30 000 ms
TDT Require
TOT presence:
Check this checkbox if TOT presence is required. Default: disabled
MGT: Enable or disable alarming of Master Guide Table errors. Only relevant
when ATSC mode is selected.
158 VB2xx GigE User’s Manual version 5.4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sencore VB200-DC and is the answer not in the manual?

Sencore VB200-DC Specifications

General IconGeneral
BrandSencore
ModelVB200-DC
CategoryNetwork Hardware
LanguageEnglish

Related product manuals