MGT Maximum
interval (ms):
The maximum allowed section repetition interval for the MGT table.
Default: 150ms
VCT:
Enable or disable alarming of Virtual Channel Table errors. Only relevant
when ATSC mode is selected.
Require TVCT: Require presence of the Terrestrial Virtual Channel Table.
Require CVCT: Require presence of the Cable Virtual Channel Table.
VCT Maximum
interval (ms):
The maximum allowed section repetition interval for the VCT table. De-
fault: 400ms
PIM/PNM:
Enable or disable alarming of Program Information Message and Pro-
gram Name Message tables. Only relevant when ATSC mode is se-
lected.
Require PIM: Require presence of the Program Information Message table.
Maximum interval
PIM (ms):
The maximum allowed section repetition interval for the PIM table. De-
fault: 500ms
Require PNM: Require presence of the Program Name Message table.
Maximum interval
PNM (ms):
The maximum allowed section repetition interval for the PNM table.
Default: 1000ms
RRT:
Enable or disable alarming of Rating Region Table errors. Only relevant
when ATSC mode is selected.
RRT Maximum
interval (ms):
The maximum allowed section repetition interval for the RRT table.
Default: 30000ms
STT:
Enable or disable alarming of System Time Table errors. Only relevant
when ATSC mode is selected.
STT Maximum
interval (ms):
The maximum allowed section repetition interval for the STT table. De-
fault: 1000ms
ATSC EIT:
Enable or disable alarming of ATSC Event Information Table errors. Only
relevant when ATSC mode is selected.
ATSC EIT Maximum
interval EIT–0 (ms):
The maximum allowed section repetition interval for the ATSC EIT–0
table. Default: 500ms
ATSC EIT Maximum
interval EIT–1 to
EIT–3 (ms):
The maximum allowed section repetition interval for the ATSC EIT–1 to
EIT–3 tables. Default: 5000ms
ATSC EIT Maximum
interval EIT–4 to
EIT–127 (ms):
The maximum allowed section repetition interval for the ATSC EIT–4 to
EIT–127 tables. Default: 30000ms
VB2xx GigE User’s Manual version 5.4 159

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sencore VB200-DC and is the answer not in the manual?

Sencore VB200-DC Specifications

General IconGeneral
BrandSencore
ModelVB200-DC
CategoryNetwork Hardware
LanguageEnglish

Related product manuals