MX-3114N SIMULATION 6 – 56
44-4
Purpose
Setting
Function (Purpose)
Used to set the conditions of the high den-
sity process control operation.
Section
Process
Operation/Procedure
1) Select an item to be set with scroll keys.
2) Enter the set value with 10-key.
3) Press [OK] key.
Set the items to the default values unless a change is specially
required.
44-6
Purpose
Adjustment
Function (Purpose)
Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
Press [EXECUTE] key.
In case of a normal completion, the result is saved.
In case of an abnormal completion, "ERROR" is displayed.
(Refer to the table below.)
In case of an ERROR, the previous correction data are saved.
Registration
substrate R scan
abnormality
REG_R GRND error
The difference between the max. value and the
min. value of the substrate detection level is
greater than the specified value when the transfer
belt rotates 2 turn
Item/Display Content
Setting
range
Default
value
A PCS_CL TARGET Color image sensor
adjustment target value
1 - 255 204
B PCS_K TARGET Black image sensor
adjustment target value
1 - 255 204
C LED_CL OUTPUT Color image sensor light
emitting start level
1 - 255 21
D LED_K OUTPUT Black image sensor light
emitting start level
1 - 255 21
E PCS ADJSTMENT
LIMIT
Color image sensor
adjustment error
allowance level
1 - 255 4
F BELT GROUND
DIF
Transfer belt one-turn
substrate detection level
difference allowance
level
1 - 255 1
G BIAS_CL
STANDARD DIF
Developing bias (for
color) reference
correction voltage
0 - 255 60
H BIAS_BK
STANDARD DIF
Developing bias (for
black) reference
correction voltage
0 - 255 0
I BIAS PATCH
INTERVAL
Toner patch making
developing bias interval
1 - 255 60
J Y_PAT TARGET ID Process control target
density level (yellow)
1 - 255 40
K M_PAT TARGET ID Process control target
density level (magenta)
1 - 255 45
L C_PAT TARGET ID Process control target
density level (cyan)
1 - 255 45
M K_PAT TARGET ID Process control target
density level (black)
1 - 255 45
N HV BK_GROUND
LIMIT
Black image sensor
adjustment error
allowance level
1 - 255 60
Error name Error content
Result display Content description
COMPLETE Normal complete
ERROR Abnormal end
INTERRUPTION Forcible interruption
Details of error display Content description
CL_SEN_ADJ_ERR Color image sensor adjustment abnormality
BK_SEN_ADJ_ERR Black image sensor adjustment abnormality
K_HV_ERR K high density process control abnormality
C_HV_ERR C high density process control abnormality
M_HV_ERR M high density process control abnormality
Y_HV _ERR Y high density process control abnormality
TIMEOUT_ERR Time out