MX-3114N SIMULATION 6 – 57
44-9
Purpose
Operation data display
Function (Purpose)
Used to display the result data of the high
density process control operation.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
Select a target display mode with [CPY/PRN], [OTHER] keys.
Mode Item/Display (*: Correction value) Content Display range
Default
value
CPY/PRN P (PROCON) BLACK : GB ***/*** DV ***/*** High density process control mode
GB/DV data (KCMY)
(Output voltage level/base voltage level)
GB: 150 - 850
DV: 0 - 600
GB: 630
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
N(M)
(NORMAL
(MIDDLE))
BLACK : GB ***/*** DV ***/*** Medium speed print mode
GB/DV data (KCMY)
(Actual output voltage level/base voltage level)
GB: 150 - 850
DV: 0 - 600
GB: 630
DV: 430
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
N(L)
(NORMAL
(LOW))
BLACK : GB ***/*** DV ***/*** Low speed print mode
GB/DV data (KCMY)
(Actual output voltage level/base voltage level)
GB: 150 - 850
DV: 0 - 600
GB: 600
DV: 400
CYAN : GB ***/*** DV ***/***
MAGENTA : GB ***/*** DV ***/***
YELLOW : GB ***/*** DV ***/***
OTHER TN/TC TN HUD AREA Toner density correction humidity area 1 - 8 4
TN HUD DATA Toner density correction humidity AD value 0 - 1023 0
TC TMP AREA Transfer correction temperature area 1 - 9 4
TC TMP DATA Transfer correction temperature AD value 0 - 1023 0
TC HUD AREA Transfer correction humidity area 1 - 9 4
TC HUD DATA Transfer correction humidity AD value 0 - 1023 0
MD HUD AREA Membrane decrease correction humidity area 1 - 8 4
MD HUD DATA Membrane decrease correction humidity AD value 0 - 1023 0
DRUM MD K STEP Drum membrane decrease correction STEP level
(KCMY)
0 - 4 0
MD C STEP
MD M STEP
MD Y STEP
MD K DRUM COUNTER Membrane decrease drum traveling distance area
(KCMY)
0 - 20 0
MD C DRUM COUNTER
MD M DRUM COUNTER
MD Y DRUM COUNTER
OTHER LIFE MD K REVISE(LIFE) : L *** M *** MC grid correction voltage level (for the drum
membrane decrease) (KCMY)
0 - 255 0
MD C REVISE(LIFE) : L *** M ***
MD M REVISE(LIFE) : L *** M ***
MD Y REVISE(LIFE) : L *** M ***
EV MD K REVISE(EV) : L *** M *** MC grid voltage correction level (for the
environment) (KCMY)
0 - 255 0
MD C REVISE(EV) : L *** M ***
MD M REVISE(EV) : L *** M ***
MD Y REVISE(EV) : L *** M ***
ALL MD K REVISE(ALL) : L *** M *** MC grid voltage correction level (for the drum
membrane decrease) (KCMY)
0 - 255 0
MD C REVISE(ALL) : L *** M ***
MD M REVISE(ALL) : L *** M ***
MD Y REVISE(ALL) : L *** M ***
LD MD K REVISE(LD) : L *** M *** Laser power correction level (for the drum
membrane decrease) (KCMY)
0 - 255 0
MD C REVISE(LD) : L *** M ***
MD M REVISE(LD) : L *** M ***
MD Y REVISE(LD) : L *** M ***
DL MD K REVISE COL (DL): L *** M *** Discharge lamp correction level (%) (for the drum
membrane decrease)
0 - 100 70
MD C REVISE COL (DL): L *** M ***
MD M REVISE COL (DL): L *** M ***
MD Y REVISE COL (DL): L *** M ***
DL EV MD K REVISE COL (DL EV): L *** M *** Discharge lamp correction level (%) (for the
environment)
-100 - 100 0
MD C REVISE COL (DL EV): L *** M ***
MD M REVISE COL (DL EV): L *** M ***
MD Y REVISE COL (DL EV): L *** M ***
CRUM DESTINATION CRUM destination (Main unit data) - -
MODEL TYPE Machine model type 0 - 1 0
CRUM DEST_K CRUM destination (CRUM data) - -
CRUM DEST_C
CRUM DEST_M
CRUM DEST_Y
CNT PROCON COUNT HV High density process control number of executions 0 - 99999999 0
PROCON COUNT HT Halftone process control number of executions 0 - 99999999 0