EasyManua.ls Logo

Sharp MX-2314N - Page 191

Sharp MX-2314N
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MX-3114N SIMULATION 6 – 58
44-12
Purpose
Operation data display
Function (Purpose)
Used to display the operation data of the
high density process control and the image
density sensor (registration sensor).
Section
Image process (Photoconductor/Develop-
ing)
Operation/Procedure
Select a display mode with [TARGET] [PATCH] keys.
44-14
Purpose
Operation data display
Function (Purpose)
Used to display the output level of the tem-
perature and humidity sensor.
Section
Process (OPC drum, development)/Fusing/
LSU
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
44-15
Purpose
Setting
Function (Purpose)
Used to set the OPC drum idle rotation.
Section
Process
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key.
The initial value must be set unless any special change is required.
The execution YES/NO of the OPC drum idle rotation is determined
by the AND condition of TIME, AREA1, and AREA 2.
To execute the OPC drum idle rotation, set item B (AREA 1) to "0,"
and item C (AREA2) to "15."
Mode Item/Display Content
Display
range
Default
value
TARGET ADK_SL (K) Development
characteristics gradient
coefficient (High density
process control
operation)
-9.99 -
9.99
0
ADK_INT(K) Development
characteristics intercept
level (High density
process control
operation 0V)
-999.9 -
999.9
0
TARGET (K) High density process
control target density
level (K)
0.00 -
255.00
0
TAR-
GET
TARGET
(C/M/Y)
High density process
control target density
level (C/M/Y)
0.00 -
255.00
0
PATCH n-1 High density process
control nth time toner
patch density level 1
(n=1-5)
0 - 255 0
n-2 Toner patch data nth
time patch 2 (n=1-5)
0 - 255 0
n-3 Toner patch data nth
time patch 3 (n=1-5)
0 - 255 0
n-4 Toner patch data nth
time patch 4 (n=1-5)
•BK only
0 - 255 0
n-5 Toner patch data nth
time patch 5 (n=1-5)
•BK only
0 - 255 0
PATCH n-1 Toner patch data nth
time patch 1 (n=6-10)
0 - 255 0
n-2 Toner patch data nth
time patch 2 (n=6-10)
0 - 255 0
n-3 Toner patch data nth
time patch 3 (n=6-10)
0 - 255 0
n-4 Toner patch data nth
time patch 4 (n=6-10)
•BK only
0 - 255 0
n-5 Toner patch data nth
time patch 5 (n=6-10)
•BK only
0 - 255 0
Item/Display Content Display range
TH_UM Fusing main thermistor
differential input level (ï‚°C) /
(AD value)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TH_UM_AD1 Fusing thermistor detection
level for compensation (ï‚°C)
/ (AD value)
Temperature:
0.0-255.0C (0.2C)
AD value: 0-1023
TH_UM_AD2 Fusing thermistor detection
level (AD value)
AD value: 0-1023
TH_LM Fusing thermistor A/D value
(temperature ï‚°C) (Fusing
roller B edge)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TH_US Fusing sub thermistor A/D
value (temperature ï‚°C)
(Fusing belt)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TEMPRATURE Process control thermistor
detection level
Temperature:
-40.0 - 60.0C (0.1C)
AD value: 0-1023
HUMIDITY Process control humidity
sensor detection level
Humidity:
5.0-90.0% (0.1%),
AD value: 0-1023
TH1_LSU LSU thermistor detection
level (A/D value) (ï‚°C)
Temperature:
5.0-60.0C (0.1C)
AD value: 0-255
Item/
Display
Content
Setting
range
Default
value
A TIME Idle rotation interval (time interval
between the previous OPC drum idle
rotation and the next one) setting (h)
0 - 255 6
B AREA1 Environmental area difference
judg
ment threshold value setting
(difference between the previous
OPC drum idle rotation and the
current one)
0 - 5 2
C AREA2 Environmental area conditions (AND
condition of the previous OPC drum
idle rotation and the current one)
1 - 15 1
D CYCLE Previous rotation time setting (sec)
in the process control when
recovered from power ON,
preheating/sleep mode.
0 - 255 0

Table of Contents