EasyManua.ls Logo

Sharp MX-2314N - Page 191

Sharp MX-2314N
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MX-3114N SIMULATION 6 – 58
44-12
Purpose
Operation data display
Function (Purpose)
Used to display the operation data of the
high density process control and the image
density sensor (registration sensor).
Section
Image process (Photoconductor/Develop-
ing)
Operation/Procedure
Select a display mode with [TARGET] [PATCH] keys.
44-14
Purpose
Operation data display
Function (Purpose)
Used to display the output level of the tem-
perature and humidity sensor.
Section
Process (OPC drum, development)/Fusing/
LSU
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
44-15
Purpose
Setting
Function (Purpose)
Used to set the OPC drum idle rotation.
Section
Process
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key.
The initial value must be set unless any special change is required.
The execution YES/NO of the OPC drum idle rotation is determined
by the AND condition of TIME, AREA1, and AREA 2.
To execute the OPC drum idle rotation, set item B (AREA 1) to "0,"
and item C (AREA2) to "15."
Mode Item/Display Content
Display
range
Default
value
TARGET ADK_SL (K) Development
characteristics gradient
coefficient (High density
process control
operation)
-9.99 -
9.99
0
ADK_INT(K) Development
characteristics intercept
level (High density
process control
operation 0V)
-999.9 -
999.9
0
TARGET (K) High density process
control target density
level (K)
0.00 -
255.00
0
TAR-
GET
TARGET
(C/M/Y)
High density process
control target density
level (C/M/Y)
0.00 -
255.00
0
PATCH n-1 High density process
control nth time toner
patch density level 1
(n=1-5)
0 - 255 0
n-2 Toner patch data nth
time patch 2 (n=1-5)
0 - 255 0
n-3 Toner patch data nth
time patch 3 (n=1-5)
0 - 255 0
n-4 Toner patch data nth
time patch 4 (n=1-5)
•BK only
0 - 255 0
n-5 Toner patch data nth
time patch 5 (n=1-5)
•BK only
0 - 255 0
PATCH n-1 Toner patch data nth
time patch 1 (n=6-10)
0 - 255 0
n-2 Toner patch data nth
time patch 2 (n=6-10)
0 - 255 0
n-3 Toner patch data nth
time patch 3 (n=6-10)
0 - 255 0
n-4 Toner patch data nth
time patch 4 (n=6-10)
•BK only
0 - 255 0
n-5 Toner patch data nth
time patch 5 (n=6-10)
•BK only
0 - 255 0
Item/Display Content Display range
TH_UM Fusing main thermistor
differential input level (ï‚°C) /
(AD value)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TH_UM_AD1 Fusing thermistor detection
level for compensation (ï‚°C)
/ (AD value)
Temperature:
0.0-255.0C (0.2C)
AD value: 0-1023
TH_UM_AD2 Fusing thermistor detection
level (AD value)
AD value: 0-1023
TH_LM Fusing thermistor A/D value
(temperature ï‚°C) (Fusing
roller B edge)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TH_US Fusing sub thermistor A/D
value (temperature ï‚°C)
(Fusing belt)
Temperature:
0 - 255C (1C)
AD value: 0-1023
TEMPRATURE Process control thermistor
detection level
Temperature:
-40.0 - 60.0C (0.1C)
AD value: 0-1023
HUMIDITY Process control humidity
sensor detection level
Humidity:
5.0-90.0% (0.1%),
AD value: 0-1023
TH1_LSU LSU thermistor detection
level (A/D value) (ï‚°C)
Temperature:
5.0-60.0C (0.1C)
AD value: 0-255
Item/
Display
Content
Setting
range
Default
value
A TIME Idle rotation interval (time interval
between the previous OPC drum idle
rotation and the next one) setting (h)
0 - 255 6
B AREA1 Environmental area difference
judg
ment threshold value setting
(difference between the previous
OPC drum idle rotation and the
current one)
0 - 5 2
C AREA2 Environmental area conditions (AND
condition of the previous OPC drum
idle rotation and the current one)
1 - 15 1
D CYCLE Previous rotation time setting (sec)
in the process control when
recovered from power ON,
preheating/sleep mode.
0 - 255 0

Table of Contents