MX-3114N SIMULATION 6 – 91
Error displays in case of abnormal end
50-24
Purpose
(This simulation is normally not used in the
market.)
Function (Purpose)
Used to display the detail data of SIM 44-2,
50-20 and 22.
Section
Operation/Procedure
This simulation is mainly used by the technical division, and is not
necessary for the market.
50-27
Purpose
Adjustment
Function (Purpose)
Used to perform the image loss adjustment
of scanned images in the FAX or image
send mode.
Section
Operation/Procedure
1) Select a target adjustment mode with [FAX] or [SCANNER]
key.
2) Select an adjustment target item with scroll key on the touch
panel.
3) Enter the set value with 10-key.
4) Press [OK] key. (The set value is saved.)
[RSPF]
Error code Error display Error content Description
Forcible end error - SUSPENDED Door open end Door open during operation
- SUSPENDED CA end CA button pressed during operation
- - OFF end Unconfirmed operation during operation (Power OFF)
Basic error 1 TONNER EMPTY Toner Empty BK or ALL Color toner EMPTY detection
2 BEFOR BEHAVIOR Other condition Other condition
4 SENSOR CALIBLATION F Calibration error F The target is not reached by 3 times of retry of F or R
5 SENSOR CALIBLATION R Calibration error R
6 SENSOR CALIBLATION FR Calibration error FR
7 TIME OVER Time error No data are obtained for 90sec from data acquisition
8 PROCESS CONTROL Process control error Process control error detection
Sub scanning
adjustment error
10 - 47 SUB XXX XXXX XXX
Main scanning
adjustment error
50 - 88 MAIN XXX XXXX XXX
Others 99 OTHER 99 Other errors Other errors
Item/Display Content Setting range Default value
FAX send A Image loss
amount setting OC
LEAD_EDGE (OC) OC lead edge image loss amount setting 0 - 100 30 (3mm)
B FRONT_REAR (OC) OC side image loss amount setting 0 - 100 20 (2mm)
C TRAIL_EDGE (OC) OC rear edge image loss amount setting 0 - 100 20 (2mm)
D Image loss
amount setting
SPF SIDE1
LEAD_EDGE (SPF_SIDE1) Front surface lead edge image loss
amount setting
0 - 100 20 (2mm)
E FRONT_REAR (SPF_SIDE1) Front surface side image loss amount
setting
0 - 100 20 (2mm)
F TRAIL_EDGE (SPF_SIDE1) Front surface rear edge image loss
amount setting
0 - 100 30 (3mm)
G Image loss
amount setting
SPF SIDE2
LEAD_EDGE (SPF_SIDE2) Back surface lead edge image loss
amount setting
0 - 100 20 (2mm)
H FRONT_REAR (SPF_SIDE2) Back surface side image loss amount
setting
0 - 100 20 (2mm)
I TRAIL_EDGE (SPF_SIDE2) Back surface rear edge image loss
amount setting
0 - 100 30 (3mm)