MX-3114N SIMULATION 6 – 95
53
53-6
Purpose
Adjustment
Function (Purpose)
Used to adjust the detection level of the
RSPF document width.
Section
Operation/Procedure
1) Open the RSPF paper feed guide to the maximum width.
2) Press [EXECUTE] key.
The maximum width detection level is recognized.
3) Open the RSPF paper feed guide to the A4R width.
4) Press [EXECUTE] key.
The A4R width detection level is recognized.
5) Open the RSPF paper feed guide to the A5R width.
6) Press [EXECUTE] key.
The A5R width detection level is recognized.
7) Open the RSPF paper feed guide to the minimum width.
8) Press [EXECUTE] key.
The minimum width detection level is recognized.
When the above operation is nor performed normally, "ERROR" is
displayed and. When the above operation is completed normally,
"COMPLETE" is displayed.
53-7
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the RSPF document size
width sensor.
Section
Operation/Procedure
1) Select an adjustment target item with scroll key on the touch
panel.
2) Enter the set value with 10-key.
3) Press [OK] key. (The set value is saved.)
[RSPF]
53-8
Purpose
Adjustment
Function (Purpose)
Used to adjust the document lead edge ref-
erence and the RSPF mode document
scan position.
Section
Operation/Procedure
Select an adjustment item with [AUTO] [MANUAL] key.
<AUTO: Document lead edge reference (RRCA) adjustment>(Auto
adjustment)
1) Set a sheet of black paper of A4 or 11"x 8.5" on the document
table.
2) Press [EXECUTE] key. (The adjustment is performed and the
adjustment value is saved.)
<MANUAL: RSPF mode document scan position adjustment>
1) Enter the set value with 10-key.
2) Press [OK] key. (The set value is saved.)
• When the adjustment value is increased, the scanner stop posi-
tion in the RSPF mode is shifted to the right.
• When the adjustment value is changed by 1, the position is
shifted by 0.1mm.
1 TRAYVOLMAX Tray size volume maximum value
2 TRAYVOLA4R Tray volume A4R size adjustment value
3 TRAYVOLA5R Tray volume A5R size adjustment value
4 TRAYVOLMIN Tray size volume minimum value
Item/Display
Setting
range
Default
value
A AD_MAX Max. width position 0 - 1023 84
B AD_P1 A4R width position 0 - 1023 509
C AD_P2 A5R width position 0 - 1023 808
D AD_MIN Min. width position 0 - 1023 961
Item/Display Content
Setting
range
Default
value
MEASUREMENT
DISTANCE
Document lead edge
measurement distance
0-255
(0.1mm unit)
-
RRCA Document lead edge
reference position
0 - 99 50
Item/Display Content
Setting
range
Default
value
A ADJUST
VALUE
RSPF mode document scan
position adjustment (Scanner
stop position adjustment)
1 - 99 5