MX-3114N SIMULATION 6 – 99
60
60-1
Purpose
Operation test/check
Function (Purpose)
Used to check the memory operations
(read/write) of the MFP PWB.
Section
Operation/Procedure
1) Press [EXECUTE] key.
Start the test.
61
61-1
Purpose
Operation test/check
Function (Purpose)
Used to check the LSU polygon motor rota-
tion and laser detection.
Section
LSU
Operation/Procedure
1) Press [EXECUTE] key.
When the operation is completed normally, [OK] is displayed.
In case of an abnormal end, [NG] is displayed.
Result display Description
OK Success
NG Fail
NONE DIMM trouble
INVALID Execution disable
Display Content
LSU TESTRESULT NG: PG Polygon mirror rotation abnormality
LSU TESTRESULT NG: K Laser abnormality (K)
LSU TESTRESULT NG: CL Laser light emitting abnormality (C,M,Y)