Parameter Description
Parameters
117
<Setting>
The higher the carrier frequency, the lower the motor acoustic noise. Unfortunately, it will
result in greater leakage current and larger noises generated by the inverter.
The higher the carrier frequency, the more energy dissipated, and the higher the
temperature of the inverter.
In case of a mechanical resonance occurring in a system within the inverter, P.72 is helpful
for improving the performance by adjusting its value.
The derating curve is as follows:
2
4
9
15
30
50
70
100
Load (%)
Carrier (KHz)
Frame AA, A/B
Frame D/E
Applicable frame below
Frame F/G
1. For the frame AA, A/B: the carrier is 9K, and the load is 100%.The load will decrease 5%
as the carrier increases 1K each time. For example: the carrier is 15K, and the load is
70%.
2. For frame D/E, the carrier is 4K, and the load is 100%.The load will decrease 10% as the
carrier increases 1K each time. For example: the carrier is 9K, and the load is 50%.
3. For frame F, the carrier is 2K, and the load is 100%.The load will decrease 10% as the
carrier increases 1K each time. For example: the carrier is 9K, and the load is 30%.
4. For the inverter type the frame includes, please refer to the introduction ofAppearance
and Dimension” in section 3.3.
Note: 1. The optimum carrier frequency shall be 8 times greater than the target frequency.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SF-GT Series and is the answer not in the manual?

Shihlin electric SF-GT Series Specifications

General IconGeneral
BrandShihlin electric
ModelSF-GT Series
CategoryInverter
LanguageEnglish

Related product manuals