5.73 Short Circuit Protection Function (P.287)
P.287 “Short circuit protection function selection
Parameter Factory setting Setting range Remarks
287 1 0~1 ---
<Setting>
Set P.287 to 0 to cancel the output end short-circuits protection function.
When P.287 is set to 1, if the output end is short, the operation panel will display the “SCP”
abnormal alarm and the inverter will stop the output.
5.74 Alarm History Parameters (P.288~P.291)
P.288 “Alarm code display option
P.289 “Alarm code
P.290 “The latest alarm status selection
P.291 “The latest alarm message
This paragraph provides the users with parameter-related information on alarm codes for
frequency, current, voltage, as well as the 12 alarm codes mentioned earlier. If P.996
operation is executed, the abnormal codes and the status messages for the occurred
alarms recorded by this set of parameters will be all cleared.
Parameter
Factory
setting
Setting
range
Remarks
288 0 0~12
The value of P.288, 1~12, corresponds to the abnormal
codes of P.289’s alarm E1~E12.
289 0 ---
290 0 0~7
When P.290=1, P.291 corresponds to the frequency
when the alarm goes off.
When P.290=2, P.
291 corresponds to the current when
the alarm goes off.
When P.290=3, P.
291 corresponds to the output
voltage when the alarm goes off.
When P.290=4, P.
291 corresponds to the accumulation
rate of temperature increase when the alarm goes off.
When P.290=5, P.291 corresponds to the (+/P)-(-/N)
voltage when the alarm goes off.
When P.290=6, P.291 corresponds to the length of time
the inverter has run before the alarm goes off.
When P.290=7, P.
291 corresponds to the operation
status code when the alarm goes off.
291 0 ---

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SF-GT Series and is the answer not in the manual?

Shihlin electric SF-GT Series Specifications

General IconGeneral
BrandShihlin electric
ModelSF-GT Series
CategoryInverter
LanguageEnglish

Related product manuals