Primary Operation
Primary operation
42
When P.79 0, the external mode is the default mode after the inverter is turned on.
Use P.79 to switch the operation mode.
Related
parameters
Values
Operation
mode
The reference
source of target
frequency
The signal source
of motor starting
Remarks
Operation
mode
selection
P.79
3
Communication
mode
Communication Communication
4
Combined
Mode 1
DU01 operation
panel
External forward
and reverse
terminals
5
Combined
Mode 2
“External voltage /
current signal”,
“combination of
multi-speed stage
levels,
HDI pulse (P.550),
PG card (A2/B2)
The
FWD
or
REV
key
of DU01
operation panel.
SW11 should be
set when the
target frequency
is given by HDI
pulse and PG
card.
6
Combined
Mode 3
Communication,
“combination of
multi-speed stage
levels” and
External JOG
(P.15)
External forward
and reverse
terminals
7
Combined
Mode 4
“External voltage /
current signal” ,
“combination of
multi-speed stage
levels,
HDI pulse (P.550),
PG card (A2/B2)
Communication
SW11 should be
set when the
target frequency
is given by HDI
pulse and PG
card.
8
Combined
Mode 5
DU01 operation
panel,
“combination of
multi-speed stage
levels” and
External JOG
(P.15)
External forward
and reverse
terminals

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SF-GT Series and is the answer not in the manual?

Shihlin electric SF-GT Series Specifications

General IconGeneral
BrandShihlin electric
ModelSF-GT Series
CategoryInverter
LanguageEnglish

Related product manuals