LEDs End cap with
int
egrated
LED
Possible cause Troubleshooting
OSSD Fiel
d
Diagnostics LEDs
1 2 3 4 5 6 7 8
O
R
ed
Ö
Red
o o o Ö
Red
o o o o Ö Red
A wiring fault has
been ident
ified at
the OSSDs or at
an input.
E.g., at an OSSD:
overvoltage, short-
circuit, cross-cir‐
cuit, permissible
load capacity
exceeded.
E.g., at an input:
invalid signal,
unexpected signal.
b
Chec
k the system
wiring for a fault.
Make sure that the
OSSDs and inputs
have been wired
correctly, see "Inte‐
gration in electrical
control", page 54.
b
Switch the voltage
supply off and back
on again.
b
If the fault con‐
tinues to persist,
replace the defec‐
tive components,
see "Ordering infor‐
mation", page 150.
O
R
ed
Ö
Red
o Ö
Red
Ö
Red
o o o o o Ö Red
A wiring fault has
been de
tected.
b
Chec
k the system
wiring for a fault.
b
Make sure that the
IO-link interface was
wired correctly.
b
Switch the voltage
supply off and back
on again.
O
Red
Ö
Red
Ö
Red
o Ö
Red
o o o o o Ö Red
Incompatible
de
vice detected.
b
F
or a sender-
receiver connection,
ensure that the
sender and receiver
devices are compat‐
ible, see "Connec‐
tion of sender and
receiver", page 59.
b
Ensure that the con‐
nected sender devi‐
ces as well as the
connected receiver
devices in a cas‐
cade are compat‐
ible, see "Cascad‐
ing", page 61.
O
Red
Ö
Y
el‐
low
EDM warning (only
if t
he external
device monitoring
function is active):
The OSSDs have
constantly been in
the OFF state
since the safety
light curtain was
switched on and
no signal is
present at the
EDM input.
Normally, this message
is displayed only briefly
after switching on and
goes out as soon as
the voltage supply for
the auxiliary contacts is
established at the con‐
tactors. If the message
is displayed for longer:
b
Check the contac‐
tors.
b
Check the wiring of
the contactors.
b
Switch the voltage
supply off and back
on again.
TROUBLESHOOTING 11
8021645/1EB0/2022-04-28 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4
135
Subject to change without notice

Table of Contents

Other manuals for SICK deTec4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK deTec4 and is the answer not in the manual?

SICK deTec4 Specifications

General IconGeneral
BrandSICK
ModeldeTec4
CategorySafety Equipment
LanguageEnglish

Related product manuals