LEDs End cap with
int
egrated
LED
Possible cause Troubleshooting
OSSD Fiel
d
Diagnostics LEDs
1 2 3 4 5 6 7 8
O
R
ed
Ö
Red
O
Red
o o o Ö
Red
o o o Ö Red
EDM fault (only if
t
he external
device monitoring
function is active):
The status of the
EDM input has not
changed within
300 ms following
a change to the
OSSD status.
OR
The status of the
EDM input has
changed even
though the OSSD
status has not.
b
Chec
k the contac‐
tors.
b
Check the wiring of
the contactors.
b
Switch the voltage
supply off and back
on again.
O
R
ed
Ö
Ö
Yel‐
low/
gree
n
o o o o o o o o Ö ÖYellow/
green
Reset of the con‐
f
iguration to fac‐
tory settings is
activated.
For additional informa‐
tion: see "Factory set‐
tings", page 93.
O
R
ed
Ö
Gree
n
Ö Green
The device is in
conf
iguration
mode following a
change to the con‐
figuration.
For additional informa‐
tion: see "Configuration
mode", page 95.
O
R
ed
Ö
Red
Ö
Red
Ö
Red
Ö
Red
Ö
Red
o o o o Ö Red
A problem occur‐
r
ed when resetting
the configuration
to factory settings.
b
R
estart configura‐
tion, see "Factory
settings", page 93.
O
R
ed
Ö
R
ed
o O
Red
o o o o o Ö
Red
Ö Red
Incompatible con‐
f
iguration of the
devices in a host
guest cascade.
b
Chec
k the configu‐
ration of the devi‐
ces. If the sender
and receiver are
connected to each
other, also check
the configuration of
the sender.
b
Switch the voltage
supply off and back
on again.
b
If the fault persists,
reset the device
to factory settings
and reconfigure it,
see "Configuration",
page 91.
11 TROUBLESHOOTING
136
O P E R A T I N G I N S T R U C T I O N S | deTec4 8021645/1EB0/2022-04-28 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK deTec4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK deTec4 and is the answer not in the manual?

SICK deTec4 Specifications

General IconGeneral
BrandSICK
ModeldeTec4
CategorySafety Equipment
LanguageEnglish

Related product manuals