13.2 Manufacturer’s checklist
Checklist for the manufacturer/installer for the installation of
electro-sensitive protective equipment (ESPE)
Details about the points listed below must be present at least during initial commissioning — they are, however,
dependent on the respective application, the specifications of which are to be controlled by the manufacturer/installer.
This checklist should be retained and kept with the machine documentation to serve as reference during recurring
tests.
1. Have the safety rules and regulations been observed in compliance with the
directives/standards applicable to the machine?
Yes No
2. Are the applied directives and standards listed in the declaration of conformity? Yes No
3. Does the protective device comply with the required category according to EN 954@1? Yes No
4. Is access to the hazardous area/hazardous point only possible through the light path/the
protective field of the ESPE?
Yes No
5. Have appropriate measures been taken to prevent (mechanical point-of-operation guarding) or
monitor unprotected presence in the hazardous area when protecting a hazardous
area/hazardous point and have these been secured against removal?
Yes No
6. Are additional mechanical protective measures fitted and secured against manipulation which
prevent reaching under, over or around the ESPE?
Yes No
7. Has the maximum stopping and/or stopping/run-down time of the machine been measured,
specified and documented (at the machine and/or in the machine documentation)?
Yes No
8. Has the ESPE been mounted such that the required safety distance from the nearest hazardous
point has been achieved?
Yes No
9. Are the ESPE devices correctly mounted and secured against manipulation after adjustment? Yes No
10. Are the required protective measures against electric shock in effect (protection class)? Yes No
11. Is the control switch for resetting the protective equipment (ESPE) or restarting the machine
present and correctly installed?
Yes No
12. Are the outputs of the ESPE (OSSDs) integrated in compliance with the required category
according to EN 954@1 and does the integration comply with the circuit diagrams?
Yes No
13. Has the protective function been checked in compliance with the test notes of this
documentation?
Yes No
14. Are the given protective functions effective at every setting of the operating mode selector
switch?
Yes No
15. Are the switching elements activated by the ESPE, e.g. contactors, valves, monitored? Yes No
16. Is the ESPE effective over the entire period of the dangerous state? Yes No
17. Is a dangerous state halted when the ESPE is switched on or off, the operating modes are
changed over, or when switching over to another protective device?
Yes No
18. Has the information label for the daily check been attached so that it is easily visible for the
operator?
Yes No
This checklist does not replace the initial commissioning, nor the regular inspection by specialist personnel.
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr

Table of Contents

Other manuals for SICK M4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK M4000 Advanced and is the answer not in the manual?

SICK M4000 Advanced Specifications

General IconGeneral
TypeMultiple light beam safety device
Enclosure ratingIP65
Supply voltage24 V DC
Safety integrity levelSIL3
Performance levelPL e
Protection RatingIP65
Operating Voltage24 V DC
Number of beams2 to 4 beams
Resolution70 mm
Ambient operating temperature-25 °C ... +55 °C
Angular ResolutionNot applicable
Operating Temperature-25 °C ... +55 °C

Related product manuals