Tag NodeId.
Identi󹪝er
Data format Unit
Displayed name and level Browse name i =
1s
t
2n
d
3r
d
4th level
Line voltage U L1-L2 max Line_volt‐
age_U_L1_L2_max_MAXP
1049 Float V
Line voltage U L1-L2 min Line_voltage_U_L1_L2_min_MAXP 1050 Float V
Line voltage U L2-L3 min Line_voltage_U_L2_L3_min_MAXP 1051 Float V
Line voltage U L3-L1 max Line_volt‐
age_U_L3_L1_max_MAXP
1052 Float V
Line voltage U L3-L1 min Line_voltage_U_L3_L1_min_MAXP 1053 Float V
Line-to-line voltage U L2-L3 max Line_to_line_volt‐
age_U_L2_L3_max_MAXP
1048 Float V
Maximum line frequency Maximum_line_frequency_MAXP 1054 Float Hz
Maximum switching element heating Maximum_switching_ele‐
ment_heating_MAXP
1055 UInt32 %
Maximum trigger current (%) Maximum_trigger_current_per‐
cent_MAXP
1056 Float %
Maximum trigger current (rms) Maximum_trigger_cur‐
rent_rms_MAXP
1057 Float A
Minimum line frequency Minimum_line_frequency_MAXP 1058 Float Hz
Number of motor overload trips Number_of_motor_over‐
load_trips_MAXP
1059 UInt32 -
Number of starts with ext. bypass Number_of_starts_with_ext._by‐
pass_MAXP
1060 UInt32 -
Operating hours - device Operating_hours___device_MAXP 1061 UInt32 s
Operating hours - motor current
120...1000 (% x Ie)
Operating_hours___motor_cur‐
rent_120...1000_(%_x_Ie)_MAXP
1065 UInt32 s
Operating hours - motor current
18...49.9 (% x Ie)
Operating_hours___motor_cur‐
rent_18...49.9_(%_x_Ie)_MAXP
1062 UInt32 s
Operating hours - motor current
50...89.9 (% x Ie)
Operating_hours___motor_cur‐
rent_50...89.9_(%_x_Ie)_MAXP
1063 UInt32 s
Operating hours - motor current
90...119.9 (% x Ie)
Operating_hours___motor_cur‐
rent_90...119.9_(%_x_Ie)_MAXP
1064 UInt32 s
Phase current I L1 max (%) Phase_current_I_L1_max_per‐
cent_MAXP
1066 Float %
Phase current I L1 max (rms) Phase_cur‐
rent_I_L1_max_rms_MAXP
1067 Float A
Phase current I L1 min (%) Phase_current_I_L1_min_per‐
cent_MAXP
1068 Float %
Phase current I L1 min (rms) Phase_cur‐
rent_I_L1_min_rms_MAXP
1069 Float A
Phase current I L2 max (%) Phase_current_I_L2_max_per‐
cent_MAXP
1070 Float %
Phase current I L2 max (rms) Phase_cur‐
rent_I_L2_max_rms_MAXP
1071 Float A