Use of the ET 200iSP distributed I/O device in device group I (mining) Category M2
The following conditions must be ful󹪝lled if the ET 200iSP is used in device group I (underground
mining operations and their overground systems) Category M2:
CAUTION
Transport and storage of the ET 200iSP
To avoid ignitable sparks, the power supply (PS) and the mounting rail of the ET 200iSP must
be packaged in shock-proof packaging for transportation and storage (e.g. for servicing)
and immediately removed from the hazardous area.
The enclosure in which the ET 200iSP is installed must be approved for device group I,
category M2.
Observe all other requirements concerning use of the ET 200iSP in the hazardous areas
given in this manual.
9.3 Electromagnetic compatibility, transport and storage conditions
De󹪝nition of EMC
Electromagnetic compatibility is the ability of electrical equipment to function satisfactorily in
its electromagnetic environment without in󹪞uencing this environment.
The ET 200iSP distributed I/O device also meets the requirements of the EMC law of the European
market. This requires that the ET 200iSP distributed I/O device meets the speci󹪝cations and
directives for electrical installation.
EMC in accordance with NE21
The ET 200iSP distributed I/O system complies with the EMC requirements of NEMUR directive
NE21.
Pulseshaped interference
The following table shows the electromagnetic compatibility of the ET 200iSP distributed I/O
device in relation to pulse-shaped interference variables.
Pulse-shaped interference Test voltage Corresponds to degree
of severity
Electrostatic discharge in accordance with
IEC 61000‑4‑2.
Air discharge: +/- 8 kV
Contact-mode discharge: +/- 6 kV
3
Burst pulses (fast transients) in accord‐
ance with IEC 61000-4-4.
+/- 2 kV (supply line)
+/- 2 kV (signal line)
3
General technical speci󹪝cations
9.3 Electromagnetic compatibility, transport and storage conditions
ET 200iSP
242 Operating Instructions, 11/2022, A5E00247483-AK

Table of Contents

Other manuals for Siemens SIMATIC ET 200iSP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200iSP and is the answer not in the manual?

Siemens SIMATIC ET 200iSP Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC ET 200iSP
CategoryI/O Systems
LanguageEnglish

Related product manuals