Supplementary system components and encoder system integration
8.1 Basic Operator Panel BOP20
SINAMICS S110
166 Manual, 07/2015, 6SL3097-4AC10-0BP5
Overview of displays and keys
Figure 8-2 Overview of displays and keys
Table 8- 1 Displays
Display
Meaning
Top left
2 positions
The active drive object of the BOP is displayed here.
The displays and key operations always refer to this drive object.
RUN
Is lit (bright) if the displayed drive is in the RUN state (in operation).
Top right
2 positions
The following is displayed in this field:
More than 6 digits: Characters that are present but cannot be seen
(e.g. "r2" 2 characters to the right are invisible,
"L1" → 1 character to the left is invisible)
Faults: Selects/displays other drives with faults
Designation of BICO inputs (bi, ci)
Designation of BICO outputs (bo, co)
Source object of a BICO interconnection to a drive object other than the active one.
S Is (bright) if at least one parameter was changed and the value was not transferred
into the non-volatile memory.
P Is lit (bright) if, for a parameter, the value only becomes effective after pressing the
P key.
C Is light (bright) if at least one parameter was changed and the calculation for con-
sistent data management has still not been initiated.
Below,
6 position
Displays, e.g. parameters, indices, faults and alarms.

Table of Contents