//M(TimerSample/"My timer")
VS2=("Stop%ntimer")
SUB(MyTimerSub)
MyVariable = MyVariable + 1
END_SUB
PRESS(VS1)
;Calls SUB "MyTimerSub" every 1000 milliseconds
START_TIMER("MyTimerSub", 1000)
END_PRESS
PRESS(VS2)
STOP_TIMER("MyTimerSub")
END_PRESS
If START_TIMER is called again for a timer already assigned to a SUB method, then the new
interval is taken over if it is different. Otherwise, the second call is ignored.
The smallest interval for the system is100 milliseconds.
If STOP_TIMER is called for a SUB method for which no timer is currently running, the call is
ignored.
Programming commands
6.3 Functions
SINUMERIK Integrate Run MyScreens (BE2)
Programming Manual, 12/2017, 6FC5397-1DP40-6BA1 191

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based