1.9.8 Channel-specific machine data
If no channel number is defined in the address token, access is always to the currently set
channel of the operating software.
If it is necessary to read data from a specific channel, the identifier u (Unit) with the desired
channel number in square brackets is added to the address. In an array-addressing, the
channel definition is the last argument in the square brackets.
Example:
$MC_RESET_MODE_MASK
or
$MC_AXCONF_GEOAX_ASSIGN_TAB[0]
$MC_RESET_MODE_MASK[u1]
or
$MC_AXCONF_GEOAX_ASSIGN_TAB[0, u1]
$MC_RESET_MODE_MASK
Generating user dialogs
1.9 Addressing components
Easy XML
96 Programming Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based