4.2 Activating the test license
If you wish to use options without any restrictions – and without purchasing a license – you
can activate these for a limited time using the test license. Six test license periods are available.
The first test license period has a longer operating time. The operating time depends on the
NCU being used. Generally, the additional test license periods are 150 operating hours of the
control system.
Note
A test license supports "short-term use" of the software in a non-productive context, e.g. use
for testing and evaluation purposes; it can be transitioned into another license.
Duration of the first test license period
NCU Operating time duration
710.3 1000 h
720.3 2000 h
730.3 3000 h
Requirement
If you wish to activate the test license, you require access level 2 (service).
Procedure
1. Press the "Activate test license" softkey.
A message informs you of the remaining number of test license
periods.
2. Press the "OK" softkey.
The test license period is now active.
The active test license periods and the remaining operating time
are now displayed.
Note
In the message line, the control displays the operating time still available for the current test
license period every hour.
Licensing
4.2 Activating the test license
SINUMERIK Operate (IM9)
76 Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1

Table of Contents

Other manuals for Siemens SINUMERIK 840D sl

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl and is the answer not in the manual?

Siemens SINUMERIK 840D sl Specifications

General IconGeneral
Control TypeCNC
Number of AxesUp to 31
Max Number of Channels10
InterfacesEthernet, PROFIBUS, PROFINET, USB
Interpolation5-axis interpolation
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
DisplayTFT color display, various sizes
Programming LanguagesDIN/ISO
Safety FeaturesSafety Integrated
PLCIntegrated PLC S7-300
Drive InterfaceSINAMICS S120
Data StorageCF card, USB
Operating SystemWindows-based