NC Commissioning with HMI Advanced
11.2 Machine and setting data
Manual
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
357
Name
The identifier of a setting data is subject to the scheme:
$ S k _
IdentifierString
where the following applies:
● $: System variable
● S: Setting data
● k: Component
k identifies the components of the NC parameterizing the appropriate machine data:
● N: NC
● C: Channel
● A: Axis
Activation
Unlike machine data, changes to setting data always become effective immediately.
Overview of machine data
The machine data is divided into the following areas:
Table 11-1 Overview of machine data
Area Description
from 1000 to 1799 Machine data for drives ($MD_....)
from 9000 to 9999 Machine data for operator panel ($MM_....)
from 10000 to 18999 NC-specific machine data ($MN_....)
from 19000 to 19999 Reserved
from 20000 to 28999 Channel-specific machine data ($MC_....)
from 29000 to 29999 Reserved
from 30000 to 38999 Axis-specific machine data ($MA_....)
from 39000 to 39999 Reserved
from 51000 to 61999 General machine data for compile cycles
from 62000 to 62999 Channel-specific machine data for compile cycles
from 63000 to 63999 Axis-specific machine data for compile cycles