NC Commissioning with HMI Advanced
11.5 Axes and spindles
Manual
458 Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
Interface signals
Table 11-47 spindle: Interface signals
DB number Bit, byte Name
Axis-specific Signals from PLC to axis/spindle
31, ... 0 Feed override
31, ... 1.7 Override active
31, ... 1.6 Position measuring system 2
31, ... 1.5 Position measuring system 1
31, ... 1.4 Follow-up mode
31, ... 1.3 Axis/spindle disable
31, ... 2.2 Spindle reset/delete distancetogo
31, ... 2.1 Controller enable
31, ... 3.6 Velocity/spindle speed limitation
31, ... 16.7 Delete S value
31, ... 16.5 Resynchronize spindle 2
31, ... 16.4 Resynchronize spindle 1
31, ... 16.3 Gear changed
31, ... 16.2-16.0 Actual gear stage A to C
31, ... 17.6 Invert M3/M4
31, ... 17.5 Resynchronize spindle during positioning 2
31, ... 17.4 Resynchronize spindle during positioning 1
31, ... 18.7 Set direction of rotation counterclockwise
31, ... 18.6 Set direction of rotation clockwise
31, ... 18.5 Oscillation speed
31, ... 18.4 Oscillation via PLC
31, ... 19.7-19.0 Spindle offset H - A
Axis-specific Signals from axis/spindle to PLC
31, ... 60.7 Position reached with exact stop fine
31, ... 60.6 Position reached with exact stop coarse
31, ... 60.5 Referenced/synchronized 2
31, ... 60.4 Referenced/synchronized 1
31, ... 60.3 Encoder limit frequency exceeded 2
31, ... 60.2 Encoder limit frequency exceeded 1
31, ... 60.0 Axis/no spindle
31, ... 61.7 Current controller active
31, ... 61.6 Speed control loop active
31, ... 61.5 Position controller active
31, ... 61.4 Axis/spindle stationary (n < n
min
)
31, ... 82.3 Change gear stage
31, ... 82.2-82.0 Set gear stage AC
31, ... 83.7 Actual direction of rotation clockwise
31, ... 83.5 Spindle in set range