Alarm, error, and system messages
7.2 OXYMAT 7 message list
Operating with the Local User Interface
262 Operating Manual, 06/2017, A5E31930478-05
Note
Message no. 150
Information on parameters that have caused configuration problems can be found in the
→
[3.01] Maintenance & Diagnostics > Current messages (Page 203) menu. The parameters
causing the problems as well as the parameters affected by t
hem are listed so that you can
start the corresponding remedial measures.
When the text "Remote service" is displayed, the parameters that cause the problems and
those affected by them can only be set with the remote service tool. Contact the service
techn
ician in charge.
Message
Cause
Remedy
No.
Text
151 Configuration restored following
fault
Content of parameter memory was
faulty but has been recovered
• Call list of current messages, look
for or filter for message type
"Config. warn.".
• Call message detail view. The
affected parameter is displayed
here. Set the value of this param-
eter within the valid input limits.
153 Factory synchronization of the
electronics faulty
Synchronization values of analyzer
module electronics faulty and cannot
be restored
Replace analyzer module
160 to
175
Main. interval 1 to 16: Maintenance interval has expired
• User-specific action
• Reset expiration time of mainte-
nance interval.
192 to
199
Ext. fault 1 to 8: External fault signaled by digital input User-specific action
200 to
207
Ext. main. alarm 1 to 8: External maintenance alarm signaled
by digital input
User-specific action
208 to
215
Ext. main. demand. 1 to 8: External maintenance demanded
signaled by digital input
User-specific action
216 to
223
Ext. main. alarm 1 to 8: External maintenance required sig-
naled by digital input
User-specific action
224
Limit 1 violated
Measured value outside limit 1
User-specific action
225
Limit 2 violated
Measured value outside limit 2
User-specific action
226
Gas warning preliminary alarm
Gas warning (preliminary alarm)
User-specific action
227 Gas warning main alarm Gas warning alarm (main alarm) User-specific action
228 to
235
Ext. measured value violates limit:
External measured value outside
warning limit 1 to 8
User-specific action
236 AutoCal 1 aborted
AutoCal could not be executed due to
a fault.
•
Check and remedy pending errors
in the list of current messages.
• Then: Execute AutoCal manually.

Table of Contents

Other manuals for Siemens SIPROCESS GA700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROCESS GA700 and is the answer not in the manual?

Siemens SIPROCESS GA700 Specifications

General IconGeneral
BrandSiemens
ModelSIPROCESS GA700
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals