9. Click OK.
10. Verify that the Syslog server is receiving log information from the meter.
NOTE: If the Enable Syslog register is enabled but the Syslog Server register does not
contain an IP address, an event is generated in the event log to indicate that syslog is
enabled with no server IP.
Syslog severity to event log priority mapping
Syslog severities map to ION event priorities (0–255).
Only four of the syslog severities are used in the mapping.
Syslog severity ION event priority name ION event priority range
2 - Critical condition High 192–255
4 - Warning condition Medium 128–191
5 - Normal but significant
condition
Low 64–127
6 - Informational None 0–63
Advanced log setup and memory optimization
You can configure your meter’s logs to help ensure the integrity of critical data and to optimize the
meter’s memory usage.
Before you configure your meter’s logs, it is important to understand how logging functions and
how the settings work together.
NOTE: Configuring your meter’s logs requires an in-depth understanding of the meter’s
memory, how the logs function and the data you are capturing.
Viewing log configuration and memory usage information
You can use ION Setup to view log settings and memory usage information for your meter’s
default logs.
This information can help you understand your log usage and how to optimize your logging
configuration for your situation.
1. Start ION Setup.
2. Open the Setup Assistant for your meter.