Technical Specifications
20169223D 4-5
NMEA0183 input data:
Calibration start command:.....$PSTOC<cr><lf>
Heading offset adjust:..............$PSTOK,,,nnn,<cr><lf>
nnn = offset adjust angle 0 – 360
degree.
PSTOK and PSTOC are Stowe Dataline proprietary sentences
4.7 Distribution Unit
Dimensions:............................ See Fig. 4-4.
Protection:...............................IP22
Weight: .................................... 3,5 kg
Ambient temperature,
storage:.......................... –25 - +70°C
operation:......................0 - +55°C
Safe distance to magnetic compass: 1.5 m (5')
Mains voltage:........................24V DC +30/–25%
Alarm voltage : ...................... 24V DC ±20 %
Input signals:
Rudder Feedback Unit:.........3400 Hz +/-20Hz/degree
Steering Lever
FU :................................. Current signal: 0-1mA (±45°)
NFU : .............................Switch contacts
D90 Distribution Unit:
Solid state output: ....... Switching low DC (19-40V) single
channel. 3A.
D91 Distribution Unit:
Solid state output: ....... Switching high DC (110V) single
channel. 1A.
D92 Distribution Unit:
Solid state output: ....... Switching high/low AC (110-220V)
single channel. 1A.
D93 Distribution Unit:
Analogue output: ........ Two independent channels with
+/-10V or 4-20mA output
D99 Distribution Unit:
Output:.......................... Switching reversible motor, max. 10A,
24VDC.