Installation
20169223D 5-9
RGC50/10/11 Gyro compass connection to AP9 MK3
9
6
3
13
12
J5
CONTROL UNIT
RGC SIGNAL
INTERFACE UNIT
V/2
COS
SIN
GND
+12V
1
2
3
4
5V/2
COS
SIN
GND
+12V
TB4
Fig. 5-10
Sine/cosine connection
2
1
J3
CONTROL UNIT
RGC SIGNAL
INTERFACE UNIT
3
4OUT Lo
OUT Hi
TB3
Lo
Hi
SERIAL I/P
Fig. 5-11
Serial line connection
RGC12 Gyro compass connection to AP9 MK3
2
1
J3
CONTROL UNIT
RGC12
CONTROL BOX
IRNL
IRNH
TB7
Lo
Hi
NMEA
IRNS
Fig. 5-12
RGC12 Serial line connection
Note ! If Dual Station is used, serial heading data can not be connected to J3, 1-2.