EasyManua.ls Logo

Sony MK7807V1 - Analog; Bks-R1617

Sony MK7807V1
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Applicable Models
BVS-A3232 Analog Audio Routing Switcher
BVS-V3232 Analog Video Routing Switcher
DVS-128 Routing Switcher
DVS-RS1616 RS-422A Remote Routing
Switcher
DVS-TC3232 Time Code Routing Switcher
HDS-X3400 Multi Bit-Rate Routing Switchers
HDS-X3600 Multi Bit-Rate Routing Switchers
HDS-X3700 Multi Bit-Rate Routing Switchers
HDS-X5800 Multi Bit-Rate Routing Switcher
Supplied Accessories
Operation and maintenance manual (1)
BNC T-bridge connector (1)
Specifications
Control signals
REMOTE 1:
S-BUS (BNC type) (1)
Data transfer method: BI-PHASE SPACE
Data transfer rate: 312.5 kb/s
Max. cable length 500 m
(when using Belden 8281, Fujikura
5C2V or equivalent 75 Ω coaxial cable).
Expandable to 1000 m with a
BKPF-L803 S-BUS Isolator/Expander
REMOTE 2:
D-sub 9-pin (1)
Data transfer method: Conforms to the
EIA RS-422A Cart+
Data transfer rate: 38.4 kb/s
RS-232C:
D-sub 9-pin male (1)
Data transfer method: 8-bit, no parity, 1
stop bit
Data transfer rate: 19.2 kb/s
General
Power requirements:
100 to 240 V AC, 50/60 Hz
Current consumption:
0.35 A
Operating temperature:
0 to 45 °C (32 to 113 °F)
Dimensions (W x H x D):
440 x 44 x 120 mm
(17 3/8 x 1 3/4 x 4 3/4 inches)
Mass:
Approx. 1.5 kg (3 lb 5 oz)
The BKS-R1617 multi-display control unit controls matrix
cross points in routers connected to an S-BUS system.
The BKS-R1617 also controls the monitoring output of
routers that have this facility. Source and destination
switching is performed with 16 buttons. The monitoring
signal can also be selected as a destination signal. The
shallow depth of the unit makes it easy to accommodate
the BKS-R1617 in front of a desk-mounted switcher
control panel.
Features
* Router control in S-BUS systems * Fully compliant with
expanded S-BUS systems * Source/destination selection
by scrolling through source and destination names using
the Selector knob * Four-digit display for each select
button * Button re-assignment using the Selector knob *
Improved monitor function for the selection of destinations
* Alternate source switching using Chop function *
Sources selectable to levels * Sources searched by
category * Access can be restricted to a defined block of
crosspoints * Large selector buttons show source and
destination name (Status shown by button color) * Several
crosspoints switchable with a single button (Phantom
function) * Route function for expanded sources * Number
of sources and destinations controlled expandable with
additional units * Control bridge between RS-422A (cart+
protocol) and S-BUS * Easy ROM update * Single cable
connection * Reduced depth helps in desk mounting
applications
BKS-R1617 Multi-Display Control Unit
Rear Panel
23
Routing Switchers
Routing Switchers
*SGC_0011-0038 02.3.16 4:59 PM Page 23