b) Split/Stack Adjustment - When you experience splitting steno outlines or multiple steno
outlines becoming one, adjust the Split/Stack Adjustment setting. It is strongly recommended
that you select the first available setting and assess the change. Turn on CNN or the equivalent
and write against the broadcast for 20 - 30 minutes.
The default setting is Balanced. Use the + and - sensors to select one of the following:
·
Less Splitting 1 - Multiple steno outlines show in your steno notes that are intended to be one
stroke.
·
Less Stacking 1 - Single steno outlines show in your steno notes that are intended to be two
strokes.
c) Transition Time - Transition time is the number of milliseconds that pass between the release
of a key stroke and when the Luminex recognizes the next key stroke. This can affect the
stacking or splitting of steno outlines. If you experience stacking or splitting steno
outlines, adjust the
Split/Stack Adjustment option first. If the Split/Stack Adjustment settings do not resolve the
splitting or stacking of steno outlines, set the Split/Stack Adjustment option to “Balanced”
before changing the Transition Time setting. It is strongly recommended that you adjust the
transition time in a small increment and assess the change. Turn on CNN or the equivalent and
write against the broadcast for 20 - 30 minutes.
The default setting is 8 milliseconds. Use the + and - sensors to choose a number between 2
and 66.
·
Lengthen transition time setting - If split steno outlines continue to show in your steno notes,
lengthening the transition time should help. Split steno outlines indicate that the transition
time is too short. Increase the transition time setting in small increments. To increase the
transition time (lengthen the time allowed for strokes to be combined into one) touch +
(plus). For example, if the Transition Time setting is 8 ms (default), touching + increases the
transition time to 10 ms.
·
Shorten the transition time setting - if stacked steno outlines continue to show in your steno
notes, shortening the transition time should help. Stacked steno outlines indicates that the
transition time is too long. Decrease the transition time setting in small increments. To
decrease the transition time (shorten the time allowed for strokes to be combined into one),
touch - (minus). For example, if the Transition Time setting is 8 ms (default), touching -
decreases the transition time to 6 ms.
d) Return to Factory Default Settings - Reset all the keyboard options to the default factory
settings. Use the - (No) or + (Yes) sensor to make your selection. If you only made changes in
Adjust Keys feature, you will not prompted to save the settings as indicated in the next step.
1. Touch OK. You are prompted to save the settings to a Keyboard profile. If you made these
adjustments while writing, after you end the job you are prompted to save the settings to a profile.