78
2019 Stenograph, L.L.C. All Rights Reserved.
78
Luminex Users Guide
Chapter 3 Writing on the Luminex
·
Off. Selecting Off means all the touch sensors are disabled while writing a job. You need to use
the touch screen menu items to navigate and to end a file.
4. To save the setting and display the Opening menu, touch OK, More, Quit.
Prompt to End Job
The Luminex can optionally prompt you with a confirmation message each time you touch the End
sensor or touch screen menu item to close a job. If you find yourself ending jobs prematurely because
you accidentally touched the End sensor, you may want to change this option. When the Confirmation
message displays, you can continue to close the job by selecting End again. Touching Cancel or
continuing to write cancels the message and the job remains open.
To set the end job confirmation prompt option:
1. From the Opening menu, touch Setup, More, Options.
2. Touch the Down/ Up sensors as necessary to highlight the Prompt to end job option.
3. Touch the Change sensor to toggle the option between Yes and No. Yes is the default.
·
Yes - means you will be prompted to confirm that you want to end the file. The following prompt
displays:
“To Confirm End of Job, press End.” To end the job, touch the End sensor now located on the
right side of the screen.
If you continue to write without press End again, the message goes away.
·
No - means that when you touch End in a job, the file will close.
4. To save the setting and display the Opening menu, touch OK, More, Quit.
Clear J-defines when turning on/ending job
J-defines made on the Luminex are sent to a J-defines file in the Luminex's memory. All dictionary
defines made when writing realtime via the USB cable to Case CATalyst V13 or higher are also sent
to the Luminex and are saved in the writer’s memory. J-defines held in memory are automatically
used for translation in subsequent files on the Luminex unless cleared. The J-defines can be cleared
(deleted) manually or automatically by selecting an action for this option. If you do not always want J-
defines made in one file to always apply to future jobs, you may want to select the setting that best fits
your needs. The default setting is Never.
To set the Clear J-defines when turning on/ending job option:
1. From the Opening menu, touch Setup, More, Options.
2. Touch the Down/ Up sensors as necessary to highlight the Clear J-defines when turning
on/ending job option.
3. Touch the Change sensor to toggle the option between the following settings. The default setting is
Never.